EN
RayClouds Photoelectric Technology Co.,Ltd.
RayClouds Photoelectric Technology Co.,Ltd.
RT-200A Response Time Measurement Device

RT-200A Response Time Measurement Device

RT-200A Response Time Analyzer ist ein von RayClouds unabhängig entwickeltes optisches Instrument.Hochempfindlicher PMT-Sensor, geringer Geräuschpegel, hoher Empfindlichkeitsbereich.RT-200A Response Time Measurement Device is the best device for grey-scale Response Time and Flicker Measurement.

RT-200A Response Time Measurement Device Übersicht

Optional RT-200M Response Time ModuleOptional RT-200M Response Time Module ist die Funktion des Response Time Module dem Instrument
gleichwertig, das mit dem System kombiniert werden kann, um Reaktionszeit und Flickermessung zu beenden usw.

RT-200A Response Time Measurement Device Charakteristisch

High Sensitivity
  • High Sensitive PMT Sensor
  • Low Noise,High Sensitive Board Design

Luminance Measurement
  • Luminance so low as 0.001cd/m 2
  • Built in CMOS Image sensor

High Speed 8 2 2 661; High Accuracy
  • Iterative Precision:: 1777x1%(Lv)
  • Accuracy

RT-200A Response Time Measurement Device Vorteil

Luminance, GAMMA und flicker
  • TelephotoObjektiv und 1Objekt186;/ 0.2Objekt186;Winkel  Design
  • Filter in der Nähe der CIE-Kurve
High Accuracy Response Time Measurement
  • 956;s Responsegeschwindigkeit,256M Datenspeicherung
  • Multiple Filterdesign
  • Gray to Gray Response Time Measurement
Accurate Measurement with High Frequency
  • Simultane Measurement FMA and JEITA modes
  • Image Control
Standard Image Signal Generator and PC graphics card output

RT-200A Response Time Measurement Device Spezifikation

Model

RT-200A

RT-200M

Receptor

PMT(CIE 1931 Y Filter)

Working Distance

450mm~∞

Viewing Angle

1º/0.2º

Image

CMOS Sensor

Sampling Rate

1K~500Kbs/S

A/D

16bit

Sampling Length

256,000,000

Trigger

Software and External

Luminance

Measurement Range

0.001 to10,000cd/m2

Accuracy*¹

±3%

Repeatability(σ)*¹

±1%

Flicker

FMA

Display range:0~100%;Accuracy:±3%

JEITA

Measurement range:≥10 cd/m2

Frequency range:0~500HZ

Accuracy:±0.5db

Measurement Analysis

Data filtering

Low pass, High pass, Band pass, Band stop, Smooth,LM

FFT

Arbitrary length Fast Fourier Transform

VESA Standard

Adaptive filtering,LM

2D and3D Graph and data export EXCEL

Interface

LAN/USB2.0

Operating temperature

5 to50ºC

Input Voltage

AC Adapter,DC12V/3A output

deckungsgleich13;* Messung der Helligkeit in den RayClouds-Bedingungen im Bereich der Lichtquelle Nr.65288unter Verwendung der 100cd/m2standard A).
*Spezifikationen und Aussehen können ohne vorherige Ankündigung geändert werden.
Gerelateerde producten
Laat een bericht achter
RT-200A Response Time Measurement Device RT-200A Response Time Measurement Device Ontdek meer oplossingen voor
Kontakt